Backflow Prevention for Coffee Machines and Soda Dispensers in Ohio
By the ACC Solutions Team
Short answer: in Ohio, any coffee machine or drink dispenser connected to a building's water line needs its own backflow protection at that connection. Ohio's plumbing code accepts an ASSE 1022, ASSE 1024 or ASSE 1032 device, or an air gap, for coffee machines and noncarbonated dispensers. Soda fountains and other carbonated dispensers need an ASSE 1022 device or an air gap, unless an ASSE 1022 device is built into the carbonator. ACC Solutions coordinates commercial plumbing in Cleveland and Cuyahoga County and quotes every job after a walkthrough.
This guide summarizes Ohio Administrative Code 4101:3-6-01, the Ohio Plumbing Code's water supply chapter (effective October 15, 2025), which adopts Chapter 6 of the 2021 International Plumbing Code with Ohio changes. We read the rule as filed and the adopted chapter text on UpCodes' Ohio Plumbing Code viewer on November 17, 2026. It's general information, not legal advice; your local building department decides what a specific installation needs.
Why a coffee maker needs backflow protection
A machine plumbed to the water supply is a cross connection: water goes in, gets heated, mixed or carbonated, and should never come back out into the building's drinking water. Section 608.1 of the code says the potable water system has to be designed, installed and maintained to keep nonpotable liquids, solids or gases from entering it through cross connections. A pressure drop in the street main or a booster pump problem in the building can pull water backward; a backflow preventer at the machine stops that.
Plug-in machines you fill by hand aren't connected to the water line, so this rule is about plumbed equipment: water-line brewers, espresso machines, tea and juice dispensers, water coolers tied to a line, and soda systems.
Which device the Ohio code accepts
| Equipment | What the Ohio Plumbing Code accepts | Section |
|---|---|---|
| Coffee machine or noncarbonated drink dispenser | ASSE 1022, ASSE 1024 or ASSE 1032 backflow preventer, or an air gap | Ohio rewrote this section (608.17.1.2) |
| Carbonated beverage dispenser (soda fountain, post-mix) | ASSE 1022 backflow preventer or an air gap, and the piping after the device's second check valve must not be affected by carbon dioxide | 608.17.1.1 |
| Carbonated dispenser with an ASSE 1022 device built into the carbonator assembly | No separate ASSE 1022 device or air gap needed at the water supply connection | Ohio exception added to 608.17.1.1 |
| Chemical dispenser (for example a dish or cleaning chemical unit on a water line) | A device listed to ASSE 1055 or an air gap fitting, per the code's device sections | 608.17.7 and the device standards |
| Humidifier without internal backflow protection | ASSE 1012 backflow preventer or an air gap | 608.17.10 |
The coffee machine line is an Ohio change. The base 2021 code text was replaced with Ohio's version, which lists three device standards plus the air gap option. Table 608.1 in the same chapter lists the ASSE 1022 device as the "backflow preventer for carbonated beverage machines" for low hazard use in 1/4 inch to 3/8 inch sizes, and the ASSE 1024 device as a dual-check-valve-type backflow preventer.
Carbonated drinks: the carbon dioxide rule
Soda systems get a stricter line. Section 608.17.1.1 says the portion of the backflow preventer downstream of its second check valve, and the piping downstream of that, "shall not be affected by carbon dioxide gas." In practice that means the device and the line after it have to be suited to carbonated service, so a fitting or pipe that is fine on a coffee line may not be fine after a carbonator.
Ohio added one exception: if an ASSE 1022 backflow preventer is provided integral to the beverage dispensing system's carbonator assembly, then neither a separate ASSE 1022 device nor an air gap is required at the water supply connection. Ask the equipment supplier, in writing, whether the carbonator has an integral ASSE 1022 device. If it doesn't, the separate device stays.
This device is not your building's backflow test
Owners often mix these up. The device at the coffee machine is an isolation device under the plumbing code: it protects your own building's water from that one machine. A testable assembly at the water service, if your water supplier requires one, protects the public system from your whole building and has its own testing schedule. Our guide to commercial backflow testing in Cleveland covers that one. Passing one doesn't satisfy the other.
Common mistakes with beverage connections
- Swapping the machine and skipping the device. A new brewer goes in, the old device comes off with the old machine, and the new one is connected straight to the line. Check the connection after any equipment change.
- Using a plain check valve. A single check valve from the hardware aisle isn't one of the listed device standards. The code names specific standards for a reason.
- A vendor install nobody looked at. Coffee and soda vendors often connect their own equipment. The property owner or tenant still has to live with the plumbing code, so ask the vendor which device standard they installed.
- Hiding the device. A device buried behind equipment can't be checked or replaced without moving the machine. Leave room to see it.
- Ignoring a dripping vent. Ohio's code describes the ASSE 1022 device as a double check valve with an intermediate atmospheric vent. A vent that drips is telling you something; have it looked at instead of capping it.
Plan it before the equipment arrives
- List every plumbed machine: brewer, espresso, soda, ice, water and chemical dispensers, with model numbers.
- Get each manufacturer's water connection requirements and ask whether a backflow device is built in.
- Decide where each device goes so it stays visible and reachable.
- Ask your local building department whether the connection needs a plumbing permit. Many permit forms, like Brook Park's 2026 plumbing permit application, ask for a fixture list.
- After install, label the device and keep the model and standard in your building file.
Other commercial fixture rules in our series: commercial service sink requirements and public restroom hot water temperature rules.
Where ACC Solutions fits
ACC Solutions coordinates commercial plumbing, and every job is quoted after a walkthrough. We don't sell, lease or service coffee or soda equipment, and we don't decide code questions; the building department does. If you're opening a break room, cafe or store in Cleveland or Cuyahoga County, send the address, the equipment list and photos of the connections under the counter to the plumbing desk at (216) 480-8899, or request a commercial plumbing project review.
ACC Solutions Team
Plumbing desk: (216) 480-8899 · Phone: (216) 238-5999 · Email: support@accmgmtsolutions.com · Contact form
Licensed General Contractor, License #CR25025171
6545 Market Ave N, Canton, OH 44721
We work asynchronously, so you can reach us by email or the contact form from any time zone; you don't need to catch us during Ohio business hours.
Frequently Asked Questions
Does a coffee machine need a backflow preventer in Ohio?
Yes, if it is connected to the water supply. Ohio's plumbing code says each coffee machine and noncarbonated beverage dispenser must be protected by an ASSE 1022, ASSE 1024 or ASSE 1032 backflow preventer, or by an air gap.
What backflow device does a soda fountain need in Ohio?
An ASSE 1022 backflow preventer or an air gap. The part of the device after its second check valve, and the piping after it, must not be affected by carbon dioxide gas.
Is a separate backflow device needed if the carbonator has one built in?
Not at the water supply connection, if the built-in device is an ASSE 1022 backflow preventer integral to the carbonator assembly. Ohio added that exception to the code.
Is the coffee machine device the same as my annual backflow test?
No. The device at the machine protects the building's water from that machine. A testable assembly at the water service, where the water supplier requires one, is a separate device with its own testing.
Can ACC check the beverage connections in my commercial space?
ACC Solutions coordinates commercial plumbing and quotes after a walkthrough. Call the plumbing desk at (216) 480-8899 with the address and your equipment list.